Content: 13.rar (34.69 KB)
Uploaded: 24.07.2022

Positive responses: 0
Negative responses: 0

Sold: 1
Refunds: 0

~ $1.34
The exact amount is on the payment page
13. Determine the silver content in copper castings according to the measured blackening of analytical lines from the spectra of samples and standard samples:
Sample CAg,% SAg,%SCu ∆S
standard 1 0.18 0.41 0.64
Standard 2 0.23 0.45 0.66
Standard 3 0.40 0.55 0.55
Sample? 0.18
The calibration graph is plotted in the coordinates ΔS from lg(СAg). We need to prepare the data for plotting by calculating the differences ΔS = SCu - SAg and the logarithm of the silver concentration.
СAg, % log(СAg) SAg SCu ΔS
0.18 -0.745 0.41 0.64 0.23
0.23 -0.638 0.45 0.66 0.21
0.40 -0.398 0.55 0.65 0.10
If you do not open the file - install the RAR archiver. Inside the archive you will find a solution in Word format.